Back to list "Lighting towers"

Lighting tower MP

Structure
Designed for lighting large open areas: airport and railway stations, industrial and sports facilities. Crown type is selected depending on the method of arrangement, number of lighting fixtures and other equipment. Stairs with safety cross-bars are installed on the lighting tower stem to provide access to the crown.
Scope of supply
Also rest zones can be arranged at different heights
Technical Specifications of Towers MP
TOWER SYMBOL TOWER STEM HEIGHT STEM PARAMETERS, mm
D
v/Dn
WEIGHT*
of STEM, 
kgг
WEIGHT*
of TOWER, 
kgг
Q-TY of OP***, pcs.
MP-16-190/395 16 190/395 750 1360 Up to 12
MP-18-200/435 18 200/435 893 1594 Up to 16
MP-20-220/440 20 220/440 907 1623 Up to 20
MP-25-350/550 25 350/550 1929 2847 Up to 25
MP-30-400/760 30 400/760 2673 3634 Up to 25
MP-35-495/920 35 495/920 4117 5178 Up to 35
MP-40-500/945 40 500/945 4400 5591 Up to 35

Dv — upper diameter of the stem
Dn — lower diameter of the stem
* weight given without installed equipment. Weight is determined individually.
** approximate weight of the tower assembly is given
*** number of spot-lights is indicative, it can be changed depending on the lighting tower construction.

The main parameters of the flange and embedded part of the Lighting Tower MP
TOWER SYMBOL NAME OF THE EMBEDDED ELEMENT CONNECTION DIMENSIONS OF THE TOWER STEM FLANGE
d n А B
MP-16-190/395 Sha 30×12×1000(А×B)  30  12 640 540
MP-18-200/435 Sha 30×12×1000(А×B) 30 12 640 540
MP-20-220/440 Sha 30×18×1000(А×B) 30 18 640 540
MP-25-350/550 Sha 30×18×1000(А×B) 30 18 900 760
MP-30-400/760 Sha 30×24×1000(А×B) 36 24 1100 950
MP-35-495/920 Sha 30×24×1000(А×B) 36 24 1200 1070
MP-40-500/945 Sha 30×24×1000(А×B) 36 24 1200 1070

d — diameter of studs used
n — number of holes in the flange
А — outer diameter of the lighting tower stem flange
B — diameter where the holes of the connecting flange of the tower stem are located

Drawings